{"id":68,"date":"2025-09-02T08:56:41","date_gmt":"2025-09-02T08:56:41","guid":{"rendered":"http:\/\/127.0.0.1\/?page_id=68"},"modified":"2026-04-19T14:05:10","modified_gmt":"2026-04-19T13:05:10","slug":"well-logging-service","status":"publish","type":"page","link":"https:\/\/pnnplus.com\/index.php\/well-logging-service\/","title":{"rendered":"Well logging service"},"content":{"rendered":"\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h1 class=\"wp-block-heading alignfull has-text-align-center has-contrast-color has-base-background-color has-text-color has-background has-link-color wp-elements-1f09a94d83e67b9f803c7d532b65c544\" style=\"border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-left-radius:10px;border-bottom-right-radius:10px;margin-right:var(--wp--preset--spacing--80);margin-left:var(--wp--preset--spacing--80)\"><strong>Well Logging Services for Formation Evaluation and Well Integrity<\/strong><\/h1>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"970\" height=\"743\" src=\"https:\/\/pnnplus.com\/wp-content\/uploads\/2026\/04\/pnnplus-pulsed-neutron-saturation-interpretation-log.png\" alt=\"PNNplus pulsed neutron interpretation log displaying fluid saturation analysis and behind\u2011casing reservoir monitoring\" class=\"wp-image-799 size-full\" title=\"\" srcset=\"https:\/\/pnnplus.com\/wp-content\/uploads\/2026\/04\/pnnplus-pulsed-neutron-saturation-interpretation-log.png 970w, https:\/\/pnnplus.com\/wp-content\/uploads\/2026\/04\/pnnplus-pulsed-neutron-saturation-interpretation-log-300x230.png 300w, https:\/\/pnnplus.com\/wp-content\/uploads\/2026\/04\/pnnplus-pulsed-neutron-saturation-interpretation-log-768x588.png 768w\" sizes=\"auto, (max-width: 970px) 100vw, 970px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h2 class=\"wp-block-heading\">Pulsed Neutron Logging Services<\/h2>\n\n\n\n<p>PNNplus 1-11\/16\u201d pulsed neutron logging tool for accurate Sigma measurement, saturation evaluation, and reservoir characterization in cased hole environments up to 175\u00b0C. <\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/pnnplus.com\/index.php\/pulsed-neutron-tool-2\/\">Explore PNN+ Tool<\/a><\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<h2 class=\"wp-block-heading\">Ultra High Temperature (UHT) Logging<\/h2>\n\n\n\n<p>PNNplus 2-1\/4\u201d UHT pulsed neutron logging tool designed for high-temperature reservoir evaluation, providing accurate saturation and Sigma measurements in cased hole environments up to 200\u00b0C (400\u00b0F) with 6-hour operating capability.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/pnnplus.com\/index.php\/uht-pulsed-neutron-2\/\">See More UHT PNN <\/a><\/div>\n<\/div>\n<\/div><figure class=\"wp-block-media-text__media\"><video controls src=\"https:\/\/pnnplus.com\/wp-content\/uploads\/2026\/04\/UHT-PNN-Tool-in-Action-Ultra-High-Temperature-Logging-Process-1.mp4\"><\/video><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:49%\">\n<figure class=\"wp-block-image size-large\">\n<div class=\"image-hover\">\n\n<img decoding=\"async\" src=\"https:\/\/pnnplus.com\/wp-content\/uploads\/2026\/04\/multi-finger-calipers-magnetic-thickness-emds-casing-inspection-1.jpg\" alt=\"Multi-finger calipers measurement with magnetic thickness and EMDS electromagnetic defectoscope for detecting corrosion, deformation, and casing damage in well logging.\" class=\"wp-image-913 normal\" title=\"\">\n\n<img decoding=\"async\" src=\"https:\/\/pnnplus.com\/wp-content\/uploads\/2025\/09\/MF_on_Services.png\" alt=\"Multi-finger caliper casing inspection service for well integrity evaluation in oil and gas wells\" class=\"hover\" title=\"\">\n\n<\/div>\n<\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:49%\">\n<h2 class=\"wp-block-heading\">Casing Inspection &amp; Well Integrity (MFC &amp; EMDS)<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Multi-finger calipers (MFC 24, 40, 56)<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Magnetic Thickness<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li>EMDS Electromagnetic Defectoscope<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Detection of corrosion, deformation, and casing damage<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-a89b3969 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/pnnplus.com\/index.php\/casing-inspection-well-integrity-with-mfc-and-emds-tools\/\">Explore MFC &amp; EMDS Technical Specifications<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<h2 class=\"wp-block-heading\">Sector \/ Radial Bond Log (SRBT)<\/h2>\n\n\n\n<p>SRBT (Sector\/Radial Bond Tool) with 79.4 mm (3 1\/8\u201d) tool diameter for cement bond evaluation and casing integrity analysis in cased hole logging environments.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\"><strong>Learn More<\/strong><\/a><\/div>\n<\/div>\n<\/div><figure class=\"wp-block-media-text__media\"><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><\/figure><div class=\"wp-block-media-text__content\">\n<h2 class=\"wp-block-heading\">Production Logging Suite (PLT Services)<\/h2>\n\n\n\n<p>Comprehensive production logging solutions including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Temperature<\/li>\n\n\n\n<li>Pressure <\/li>\n\n\n\n<li>Water hold-up <\/li>\n\n\n\n<li>Fluid density <\/li>\n\n\n\n<li>Flow meter<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\">Details<\/a><\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<h2 class=\"wp-block-heading\">The Noise Spectrum Tool<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Downhole noise analysis (100 Hz \u2013 12.7 kHz)<\/li>\n\n\n\n<li>Fluid identification &amp; flow behavior<\/li>\n\n\n\n<li>Casing leak &amp; cement channeling detectionImproved well integrity diagnostics<\/li>\n\n\n\n<li>Oil, gas &amp; water wells<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\">Details<\/a><\/div>\n<\/div>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1007\" height=\"785\" src=\"https:\/\/pnnplus.com\/wp-content\/uploads\/2026\/04\/noise-spectrum-tool-nst16-logfile-downhole-noise-analysis.png\" alt=\"Noise Spectrum Tool NST logfile displaying downhole noise spectra for fluid identification, leak detection, and cement channeling analysis\" class=\"wp-image-792 size-full\" title=\"\" srcset=\"https:\/\/pnnplus.com\/wp-content\/uploads\/2026\/04\/noise-spectrum-tool-nst16-logfile-downhole-noise-analysis.png 1007w, https:\/\/pnnplus.com\/wp-content\/uploads\/2026\/04\/noise-spectrum-tool-nst16-logfile-downhole-noise-analysis-300x234.png 300w, https:\/\/pnnplus.com\/wp-content\/uploads\/2026\/04\/noise-spectrum-tool-nst16-logfile-downhole-noise-analysis-768x599.png 768w\" sizes=\"auto, (max-width: 1007px) 100vw, 1007px\" \/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-c8623e60 wp-block-group-is-layout-constrained\" style=\"margin-top:0;margin-bottom:var(--wp--preset--spacing--60)\">\n<div class=\"wp-block-cover alignwide is-light has-custom-content-position is-position-top-right\" style=\"border-style:none;border-width:0px;border-radius:0px;margin-top:var(--wp--preset--spacing--20);margin-bottom:var(--wp--preset--spacing--20);padding-right:0;padding-left:0;min-height:429px;aspect-ratio:unset;\"><img loading=\"lazy\" decoding=\"async\" width=\"906\" height=\"632\" class=\"wp-block-cover__image-background wp-image-202\" alt=\"Multi-finger caliper casing inspection service for well integrity evaluation in oil and gas wells\" src=\"https:\/\/pnnplus.com\/wp-content\/uploads\/2025\/09\/MF_on_Services.png\" style=\"object-position:56% 12%\" data-object-fit=\"cover\" data-object-position=\"56% 12%\" title=\"\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-0 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-container-core-cover-is-layout-a52d1dc9 wp-block-cover-is-layout-flow\">\n<p class=\"has-text-align-right has-text-color has-link-color has-x-large-font-size wp-elements-fdfe99140d9cbc072d10e10aa68dc402\" style=\"color:#020039;margin-right:var(--wp--preset--spacing--60);margin-left:var(--wp--preset--spacing--60);font-style:normal;font-weight:700\">Let&#8217;s talk about our well services!<\/p>\n\n\n\n<p class=\"has-text-align-right has-text-color has-link-color wp-elements-da9fc13310d479e4d74098f307ee9118\" style=\"color:#020039;margin-right:var(--wp--preset--spacing--60);margin-left:var(--wp--preset--spacing--60);font-style:normal;font-weight:700\">We have solutions for your cased hole logging requirements<\/p>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-a89b3969 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/pnnplus.com\/index.php\/articles\/\"><strong>Discover More<\/strong><\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Well Logging Services for Formation Evaluation and Well Integrity Pulsed Neutron Logging Services PNNplus 1-11\/16\u201d pulsed neutron logging tool for accurate Sigma measurement, saturation evaluation, and reservoir characterization in cased hole environments up to 175\u00b0C. Ultra High Temperature (UHT) Logging PNNplus 2-1\/4\u201d UHT pulsed neutron logging tool designed for high-temperature reservoir evaluation, providing accurate saturation [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-68","page","type-page","status-publish","hentry"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/pnnplus.com\/index.php\/wp-json\/wp\/v2\/pages\/68","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pnnplus.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/pnnplus.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/pnnplus.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pnnplus.com\/index.php\/wp-json\/wp\/v2\/comments?post=68"}],"version-history":[{"count":74,"href":"https:\/\/pnnplus.com\/index.php\/wp-json\/wp\/v2\/pages\/68\/revisions"}],"predecessor-version":[{"id":937,"href":"https:\/\/pnnplus.com\/index.php\/wp-json\/wp\/v2\/pages\/68\/revisions\/937"}],"wp:attachment":[{"href":"https:\/\/pnnplus.com\/index.php\/wp-json\/wp\/v2\/media?parent=68"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}