{"id":425,"date":"2026-03-30T15:00:13","date_gmt":"2026-03-30T14:00:13","guid":{"rendered":"https:\/\/pnnplus.com\/?page_id=425"},"modified":"2026-04-09T12:07:27","modified_gmt":"2026-04-09T11:07:27","slug":"pulsed-neutron-tool-2","status":"publish","type":"page","link":"https:\/\/pnnplus.com\/index.php\/pulsed-neutron-tool-2\/","title":{"rendered":"pnnPlus"},"content":{"rendered":"\n<div class=\"wp-block-media-text is-stacked-on-mobile my-custom-block\" style=\"grid-template-columns:20% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"344\" height=\"2560\" src=\"https:\/\/pnnplus.com\/wp-content\/uploads\/2026\/03\/Pnnplus-String-new-scaled.png\" alt=\"Ultra high temperature pulsed neutron neutron tool for saturation logging up to 200\u00b0C in harsh oil and gas wells\" class=\"wp-image-433 size-full\" title=\"\" srcset=\"https:\/\/pnnplus.com\/wp-content\/uploads\/2026\/03\/Pnnplus-String-new-scaled.png 344w, https:\/\/pnnplus.com\/wp-content\/uploads\/2026\/03\/Pnnplus-String-new-768x5718.png 768w, https:\/\/pnnplus.com\/wp-content\/uploads\/2026\/03\/Pnnplus-String-new-275x2048.png 275w\" sizes=\"auto, (max-width: 344px) 100vw, 344px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h1 class=\"wp-block-heading has-large-font-size\"><strong>PNN &#8211; <strong>1400.0000 <\/strong>PULSED NEUTRON NEUTRON TOOL<\/strong><\/h1>\n\n\n\n<p class=\"has-medium-font-size\">PNN measures Sigma, the ability of material to capture thermal neutrons, in capture units (c.u.).<\/p>\n\n\n\n<p class=\"has-medium-font-size\">PNN counts directly the thermal neutrons reaching the detectors after their interaction with the surrounding formation; therefore, the usual inference applied by common Thermal Decay tools\u2014where gamma rays are counted and high counts indicate high Sigma values\u2014is inverted with the PNN tool, where high counts correspond to low Sigma values. This has the significant advantage of reducing statistical uncertainties, particularly for low Sigma values.<\/p>\n\n\n\n<p class=\"has-medium-font-size\">This direct measurement approach allows better differentiation in environments with low Sigma values, such as formations containing fresh water, oil, and\/or gas in the pore spaces, effectively overcoming the low-salinity formation water limitation commonly associated with standard Thermal Decay Time tools. Additionally, neutron readings are less affected by neutron activation; therefore, time-driven stop-check logging in areas of interest can further reduce statistical uncertainties at any desired depth.<\/p>\n\n\n\n<p class=\"has-medium-font-size\">All of this makes the pnnPlus tool, in conjunction with our PNN processing and analysis, a highly competitive behind-casing formation evaluation tool for high to moderate water salinity formations, and the ultimate thermal decay solution for evaluating lower salinity and lower porosity formations.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-color has-link-color has-large-font-size wp-elements-ce21b4485f77e6ac1d11352c72a69020\" style=\"color:#020039;font-style:normal;font-weight:800\">PNN <strong>Application&nbsp;<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-medium-font-size\">Determination of water saturation behind casing<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Porosity evaluation<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Estimation of remaining hydrocarbon reserves<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Identification of oil\u2013water, gas\u2013water, and gas\u2013oil contacts<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Monitoring of reservoir dynamics and fluid movement<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Evaluation of low-salinity formations<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Applications in geothermal energy projects<\/li>\n<\/ul>\n\n\n\n<p class=\"has-medium-font-size\">PNN technology is particularly effective in complex reservoir conditions where conventional thermal decay tools face limitations, especially in low-salinity and low-porosity environments.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-color has-link-color has-large-font-size wp-elements-8c429f58c0ce3447bb8427d78ec75567\" style=\"color:#020039\"><strong>PNN Operation<\/strong><\/h2>\n\n\n\n<p class=\"has-medium-font-size\">The formation is bombarded with pulses of high-energy neutrons (14 MeV) generated by the tool. These neutrons interact with the surrounding atoms, and during the time interval between successive pulses, the population of thermal neutrons reaching the detectors is measured.<\/p>\n\n\n\n<p class=\"has-medium-font-size\">The tool uses two neutron detectors, each with 60 time channels, to sample the thermal neutron population over time. The neutron counts recorded in each channel are used to compute the decay rate, which is equivalent to measuring how quickly thermal neutrons are absorbed by the formation.<\/p>\n\n\n\n<p class=\"has-medium-font-size\">The greater the ability of the formation fluids and minerals to capture thermal neutrons, the higher the resulting Sigma value.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-large-font-size\" style=\"font-style:normal;font-weight:800\">PNN TOOL SPECIFICATIONS:<\/h2>\n\n\n\n<figure class=\"wp-block-table my-table-white has-small-font-size\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0;font-style:normal;font-weight:800\"><table class=\"has-contrast-color has-text-color has-background has-link-color has-fixed-layout\" style=\"background-color:#00000029;border-width:9px\"><tbody><tr><td class=\"has-text-align-right\" data-align=\"right\"><strong>Max Temperature:<\/strong><\/td><td>175\u00b0C (350 \u00b0F)<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\"><strong>Max Pressure:<\/strong><\/td><td>103 MPa (15,000 psi)<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\"><strong>Tool Length:<\/strong><\/td><td>5.110 mm (201,18&#8243;)<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">Tool OD:<\/td><td>43 mm (1-11\/16\u201d)<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">Min Hole Diameter:&nbsp;<\/td><td>47.6 mm (1-7\/8&#8243;)<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">Tool Weight:&nbsp;<\/td><td>31,57 kg (69,60 lb)<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">Logging Speed:<\/td><td>2.14 m\/min (7 ft\/min)<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">Recommended Borehole Fluid:<\/td><td>Any<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">Tool Voltage:<\/td><td>160 VDC<\/td><\/tr><tr><td class=\"has-text-align-right\" data-align=\"right\">Tool Current:<\/td><td>40mA&nbsp;&nbsp; [generator off]<br>~100mA [generator on]<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div class=\"wp-block-file aligncenter\"><a id=\"wp-block-file--media-80bc30ea-4af1-4cd1-8092-fb51f14851bb\" href=\"https:\/\/pnnplus.com\/wp-content\/uploads\/2025\/09\/14000000_pnnplus_with_activation_gamma.pdf\"><strong>PNN TOOL TECHNICAL SPECIFICATIONS<\/strong><\/a><a href=\"https:\/\/pnnplus.com\/wp-content\/uploads\/2025\/09\/14000000_pnnplus_with_activation_gamma.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-80bc30ea-4af1-4cd1-8092-fb51f14851bb\">Download<\/a><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-cover alignfull has-custom-content-position is-position-top-center\"><img loading=\"lazy\" decoding=\"async\" width=\"1025\" height=\"428\" class=\"wp-block-cover__image-background wp-image-298 size-full\" alt=\"PNNplus saturation logging with PNN tool in oil and gas well for reservoir evaluation\" src=\"https:\/\/pnnplus.com\/wp-content\/uploads\/2025\/09\/pnn_Log_.png\" data-object-fit=\"cover\" title=\"\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-accent-6-background-color has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container has-global-padding is-layout-constrained wp-block-cover-is-layout-constrained\">\n<p class=\"has-text-align-center has-base-color has-text-color has-background has-link-color has-large-font-size wp-elements-52e753a76c1f81f64803b7090c361372\" style=\"border-top-left-radius:5px;border-top-right-radius:5px;border-bottom-left-radius:5px;border-bottom-right-radius:5px;background-color:#696969b0;padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20);font-style:normal;font-weight:800\"><a href=\"https:\/\/pnnplus.com\/index.php\/pnn-file\/\" data-type=\"page\" data-id=\"420\">PNNplus pulsed neutron tool fully is compatible with Warrior logging software systems<\/a><\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-a89b3969 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-base-color has-text-color has-background has-link-color has-medium-font-size has-custom-font-size wp-element-button\" href=\"https:\/\/pnnplus.com\/index.php\/pnn-file\/\" style=\"border-radius:5px;background-color:#35353594;font-style:normal;font-weight:900\">View more<\/a><\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n\n\n\n<div style=\"height:357px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-f1e1596d wp-block-group-is-layout-constrained\" style=\"margin-top:-350px;padding-top:0;padding-bottom:0\"><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-425","page","type-page","status-publish","hentry"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/pnnplus.com\/index.php\/wp-json\/wp\/v2\/pages\/425","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pnnplus.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/pnnplus.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/pnnplus.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pnnplus.com\/index.php\/wp-json\/wp\/v2\/comments?post=425"}],"version-history":[{"count":40,"href":"https:\/\/pnnplus.com\/index.php\/wp-json\/wp\/v2\/pages\/425\/revisions"}],"predecessor-version":[{"id":647,"href":"https:\/\/pnnplus.com\/index.php\/wp-json\/wp\/v2\/pages\/425\/revisions\/647"}],"wp:attachment":[{"href":"https:\/\/pnnplus.com\/index.php\/wp-json\/wp\/v2\/media?parent=425"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}